DA2-B0-34-450-121-C [Carling Technologies]

Circuit Breakers 5 A TWO POLE;
DA2-B0-34-450-121-C
型号: DA2-B0-34-450-121-C
厂家: Carling Technologies    Carling Technologies
描述:

Circuit Breakers 5 A TWO POLE

电路保护
文件: 总8页 (文件大小:1579K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
D-Series  
Circuit Breaker  
Designed for snap-on-back panel rail mounting on either  
a 35mm x 7.5mm, or a 35mm x 15mm Symmetrical Din  
Rail, allowing rapid and simple mounting and removal  
of the breaker. It features recessed, wire-ready, touch-  
proof, shock-resistant terminals, suitable for automatic  
screwdriver assembly, as well as “Dead Frontconstruction  
characteristics.  
Available with a Visi-Rocker two-color actuator, which  
can be specified to indicate either the ON or the TRIPPED/  
OFF mode, or solid color rocker or handle type actuators.  
All actuator types fit in the same industry standard panel  
cutouts.  
Features:  
Š
0.02 - 50 Amps  
Š
480 VAC or 65 VDC  
Š
1-4 poles (Handle)  
Š
1-3 poles (Rocker)  
Š
Choice of Time Delays  
Š
DIN rail mounting  
Š
Precise temperature independent operation  
Š
Wiping contacts – mechanical linkage with two-step  
Š
Finger safe terminals  
Š
Common trip linkage between poles – ensures that an  
overload in one pole will trip all adjacent poles  
Notes:  
1
2
All dimensions are in inches [millimeters].  
Tolerance ±.020 [.51] unless otherwise specified.  
Carling Technologies, Inc.  
60 Johnson Avenue • Plainville, CT 06062  
Phone: (860) 793-9281 • Fax: (860) 793-9231  
Email: sales@carlingtech.com • www.carlingtech.com  
|
2
D-Series Circuit Breaker - General Specifications  
Mechanical  
Electrical  
Maximum Voltage  
AC, 480 wye/277 VAC  
(See Table A), 50/60 Hz, 65VDC  
Endurance  
10,000 ON-OFF operations @ 6  
per minute; with rated Current  
and Voltage.  
All D-Series Circuit Breakers will  
trip on overload, even when  
actuator is forcibly held in the ON  
position.  
Standard Current Coils 0.100, 0.250, 0.500, 0.750, 1.00,  
2.50, 5.00, 7.50, 10.0, 15.0, 20.0,  
25.0, 30.0, 35.0, 40.0 & 50.0.  
Trip Free  
Other ratings available -  
consult factory.  
Standard Voltage Coils DC - 6V, 12V; AC - 120V, other  
ratings available, see ordering  
scheme.  
Trip Indication  
The operating actuator moves  
positively to the OFF position  
when an overload causes the  
breaker to trip.  
Insulation Resistance  
Minimum of 100 Megohms at 500  
VDC.  
Physical  
Number of Poles  
Dielectric Strength  
UL, CSA: 1960 V 50/60 Hz for one  
minute between all electrically  
isolated terminals. D-Series circuit  
breakers comply with the 8mm  
spacing and 3750V 50/60 Hz  
dielectric requirements from  
hazardous voltage to operator  
accessible surfaces and between  
adjacent poles per Publications  
EN 60950 and VDE 0805.  
Rocker Type: 1-3; Handle Type:  
1-4  
Internal Circuit Config. Switch Only and Series Trip with  
current or voltage trip coils.  
Weight  
Approximately 128 grams/pole  
(Approximately 4.57 ounces/pole)  
Housing - Black; Actuator - See  
Ordering Scheme.  
Mounts on a standard 35mm  
Symmetrical DIN Rail (35 x 7.5 or  
35 x 15mm per DIN EN5002).  
Standard Colors  
Mounting  
Resistance, Impedance Values from Line to Load Terminal  
- based on Series Trip Circuit  
Breaker  
RESISTANCE PER POLE VALUES  
from Line to Load Terminals  
(Values Based on Series Trip Circuit Breaker)  
Environmental  
Designed and tested in accordance with requirements of  
specification MIL-PRF-55629 & MIL-STD-202 as follows:  
Shock  
Withstands 100 Gs, 6ms, sawtooth  
while carrying rated current per  
Method 213, Test Condition “I”.  
Instantaneous and ultra-short  
curves tested @ 90% of rated  
current.  
Vibration  
Withstands 0.060” excursion from  
10-55 Hz, and 10 Gs 55-500 Hz,  
at rated current per Method 204C,  
Test Condition A. Instantaneous  
and ultra-short curves tested at  
90% of rated current.  
Moisture Resistance  
Method 106D, i.e., ten 24-hour  
cycles @ + 25°C to +65°C, 80-  
98% RH.  
Pulse Tolerance Curves  
Salt Spray  
Method 101, Condition A (90-95%  
RH @ 5% NaCl Solution, 96 hrs).  
Method 107D, Condition A (Five  
cycles @ -55°C to +25°C to +85°C  
to +25°C).  
Thermal Shock  
Operating Temperature -40° C to +85° C  
*Manufacturer reserves the right to change product specification without prior notice.  
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231  
Email: sales@carlingtech.com • www.carlingtech.com  
|
D-Series Circuit Breaker - General Specifications  
3
Electrical Tables  
Table A: Lists UL Recognized, CSA Accepted and VDE Certified configurations and performance capabilities as a  
Component Supplementary Protector.  
Table A Notes:  
1
2
DC and 1Phase 277 V ratings are 1 or 2 poles breaking. Three phase ratings are 3 poles breaking.  
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full  
load amps not to exceed 150 A for 250V rating and 125 A for 277 and 480 V ratings.  
UL recognition and CSAAcceptance at 480 volts refers to 3 and 4 pole versions, used only in a 3 phase WYE connected  
circuit or 2 pole versions connected with 2 poles breaking 1 phase and backed up with series fusing per note 2  
3
Agency Certifications  
Component Supplementary  
Protector under Class 3215 30,  
File 047848 0 000  
UL Recognized  
CSA Accepted  
Component Recognition Program  
UL Standard 1077  
as Protectors, Supplementary  
(Guide QVNU2, File E75596)  
CSA Standard C22.2 No. 235  
EN60934, VDE 0642 under File  
No. 10537  
UL Listed  
UL Standard 508  
VDE Certified  
Switches, Industrial Control  
(Guide NRNT2, File E148683)  
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231  
Email: sales@carlingtech.com • www.carlingtech.com  
|
4
D-Series Handle & Rocker – Ordering Scheme  
D A 3 B0  
450 1 2 1 C  
10  
8
9
10  
Agency  
Approval  
1
2
3
4
5
6
7
Actuator  
Color  
Mounting/  
Voltage  
Series  
Actuator  
Poles  
Circuit  
Frequency  
& Delay  
Current Rating  
Terminal  
1 SERIES  
D
7 CURRENT RATING (AMPERES)  
CODE AMPERES  
020 0.020  
025 0.025  
030 0.030  
050 0.050  
075 0.075  
080 0.080  
085 0.085  
210 0.100  
215 0.150  
220 0.200  
225 0.250  
230 0.300  
235 0.350  
240 0.400  
245 0.450  
250 0.500  
255 0.550  
260 0.600  
265 0.650  
270 0.700  
275 0.750  
280 0.800  
285 0.850  
410 1.000  
512 1.250  
413 1.300  
414 1.400  
415 1.500  
517 1.750  
420 2.000  
522 2.250  
425 2.500  
527 2.750  
430 3.000  
532 3.250  
435 3.500  
436 3.600  
440 4.000  
445 4.500  
547 4.750  
450 5.000  
455 5.500  
460 6.000  
465 6.500  
470 7.000  
572 7.250  
475 7.500  
480 8.000  
485 8.500  
490 9.000  
495 9.500  
610 10.000  
710 10.500  
611 11.000  
711 11.500  
612 12.000  
712 12.500  
613 13.000  
614 14.000  
615 15.000  
616 16.000  
617 17.000  
618 18.000  
619 19.000  
620 20.000  
621 21.000  
622 22.000  
623 23.000  
624 24.000  
625 25.000  
626 26.000  
627 27.000  
628 28.000  
629 29.000  
630 30.000  
632 32.000  
635 35.000  
640 40.000  
645 45.000  
650 50.000  
2 ACTUATOR1  
Handle2  
A
B
Handle, one per pole  
Handle, one per multipole unit  
Visi-Rocker3  
C
D
E
F
G
H
Indicate ON, vertical legend  
Indicate ON, horizontal legend  
Indicate ON, no legend (VDE approval not available with no legend)  
Indicate OFF, vertical legend  
Indicate OFF, horizontal legend  
Indicate OFF, no legend (VDE approval not available with no legend)  
Single Color Rocker3  
J
K
L
Vertical legend  
Horizontal legend  
No legend (VDE approval not available with no legend)  
OR VOLTAGE COIL (VOLTS, MIN. TRIP RATING)5  
A06 6 DC, 5 DC  
A12 12 DC, 10 DC  
A18 18 DC, 15 DC  
A24 24 DC, 20 DC  
A32 32 DC, 25 DC  
A48 48 DC, 40 DC  
A65 65 DC, 55 DC  
J06 6 AC, 5 AC  
J12 12 AC, 10 AC  
J18 18 AC, 15 AC  
J24 24 AC, 20 AC  
J48 48 AC, 40 AC  
K20 120 AC, 65 AC  
L40 240 AC, 130 AC  
7 TERMINAL  
1
2
#10 Screw & Pressure Plate for Direct Wire Connection  
#10 Screw without Pressure Plate  
3 POLES  
1
2
3
4
One  
Two  
Three  
Four  
8 ACTUATOR COLOR & LEGEND  
Actuator or  
Visi-Color Marking:  
Marking Color:  
Single Color  
4 CIRCUIT  
Visi-Rocker  
A0  
B0  
C0  
Switch Only (No Coil)4  
Series Trip (Current)  
Series Trip (Voltage)  
Color  
White  
Black  
Red  
I-O ON-OFF Dual  
Rocker/Handle (Actuator Black)7  
A
C
F
B
D
G
J
1
2
3
4
5
6
7
8
Black  
White  
White  
White  
White  
Black  
Black  
Black  
White  
N/A  
Red  
Green  
Blue  
H
K
M
P
R
Green  
Blue  
5 FREQUENCY & DELAY  
L
03  
105  
11  
12  
14  
16  
205  
21  
22  
24  
DC 50/60Hz, Switch Only  
DC Instantaneous  
DC Ultra Short  
DC Short  
DC Medium  
26  
32  
34  
36  
50/60Hz Long  
DC, 50/60Hz Short  
DC, 50/60Hz Medium  
DC, 50/60Hz Long  
50/60Hz Short, Hi-Inrush  
50/60Hz Medium, Hi-Inrush  
50/60Hz Long, Hi-Inrush  
DC, Short, Hi-Inrush  
DC, Medium, Hi-Inrush  
DC, Long, Hi-Inrush  
Yellow  
Gray  
Orange  
N
Q
S
Yellow  
Gray  
Orange  
426  
446  
466  
526  
546  
566  
DC Long  
9 MOUNTING/VOLTAGE  
MOUNTING STYLE  
Threaded Insert  
50/60Hz Instantaneous  
50/60Hz Ultra Short  
50/60Hz Short  
VOLTAGE  
1
6-32 x 0.195 inches  
6-32 X 0.195 inches  
ISO M3 x 5mm  
< 300  
≥ 300  
< 300  
≥ 300  
50/60Hz Medium  
C8  
2
D8  
ISO M3 x 5mm  
Notes:  
1
2
Handle breakers available up to four poles. Rocker breakers available up to three poles.  
Actuator Code:  
A: Multi-pole units factory assembled with common handle tie.  
B: Handle location as viewed from front of breaker:  
2 pole - left pole  
10 AGENCY APPROVAL  
C
UL Recognized & CSA Accepted  
VDE Certified, UL Recognized & CSA Accepted  
D9  
3 pole - center pole  
4 pole - two handles at center poles  
Multipole rocker breakers have one rocker per breaker, as viewed from the front of the  
panel. Two pole - left pole. Three pole - center pole  
≤ 30A, select Current Rating code 630. 31-50A, select Current Rating code 650.  
Voltage coil only available with delay codes 10 & 20.  
Available to 50A max with circuit code BO only.  
Color shown is visi and legend with remainder of rocker black.  
≥ 300V: Three pole breaker 3Ø or 2 pole breaker 1Ø, UL/CSA limited to 30 FLA max.  
VDE Approval requires Dual (I-O, ON-OFF) or I-O markings  
3
4
5
6
7
8
9
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231  
Email: sales@carlingtech.com • www.carlingtech.com  
|
D-Series – Circuit & Terminal Diagram  
5
Notes:  
1
2
All dimensions are in inches [millimeters].  
Tolerance ±.020 [.51] unless otherwise specified.  
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231  
Email: sales@carlingtech.com • www.carlingtech.com  
|
6
D-Series Rocker – Form & Fit Drawings  
Notes:  
1
2
3
4
All dimensions are in inches [millimeters].  
Tolerance ±.020 [.51] unless otherwise specified.  
Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON.  
For pole orientation with horizontal legend, rotate front view clockwise 90°.  
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231  
Email: sales@carlingtech.com • www.carlingtech.com  
|
D-Series – Form & Fit Drawings  
7
Notes:  
1
2
All dimensions are in inches [millimeters].  
Tolerance ±.010 [.25] unless otherwise specified.  
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231  
Email: sales@carlingtech.com • www.carlingtech.com  
Worldwide Headquarters  
Carling Technologies, Inc.  
60 Johnson Avenue • Plainville, CT 06062  
Phone: (860) 793-9281 • Fax: (860) 793-9231  
Email: sales@carlingtech.com • www.carlingtech.com  
East Region Sales Office, CT • ersm@carlingtech.com  
Midwest Region Sales Office, IL • mrsm@carlingtech.com  
West Region Sales Office, CA • wrsm@carlingtech.com  
Asia-Pacific Headquarters  
Carling Technologies, Asia-Pacific Ltd.,  
Kowloon, Hong Kong  
Int + 852-2737-2277 • Fax: Int + 852-2736-9332  
Email: sales@carlingtech.com.hk  
Shenzhen, China • shenzhen@carlingtech.com  
Shanghai, China • shanghai@carlingtech.com  
Pune, India • india@carlingtech.com  
Kaohsiung, Taiwan • taiwan@carlingtech.com  
Yokohama, Japan • japan@carlingtech.com  
Europe/Middle East/Africa Headquarters  
Carling Technologies LTD  
4 Airport Business Park, Exeter Airport,  
Clyst Honiton, Exeter, Devon, EX5 2UL, UK  
Int + 44 1392-364422 • Fax: Int + 44 1392-364477  
Email: ltd.sales@carlingtech.com  
GmbH, Germany • gmbh@carlingtech.com  
SAS, France • sas@carlingtech.com  
REV_CB_D_01_2014  

相关型号:

DA2-B0-34-610-121-C

Circuit Breakers 10 A TWO POLE
Carling Techn

DA2-B0-34-615-121-C

Circuit Breakers 15 A TWO POLE
Carling Techn

DA2-B0-34-620-121-C

Circuit Breakers 20 A TWO POLE
Carling Techn

DA201

FM STEREO TUNER MODULE
ETC

DA2025-AL

SMT Planar Transformer
COILCRAFT

DA2025-ALB

SMPS Transformer, 100W, ROHS COMPLIANT
COILCRAFT

DA2025_13

SMT Planar Transformer
COILCRAFT

DA203

Rectifier Diode, 2 Element, 0.1A, 20V V(RRM), Silicon,
ROHM

DA2032-AL

Flyback Transformers
COILCRAFT

DA2032-ALB

SMPS Transformer, ROHS COMPLIANT
COILCRAFT

DA2032-AL_

Flyback Transformers
COILCRAFT

DA2032_13

Flyback Transformers
COILCRAFT